 Standards and Certifications
Below is information on SIXNET product certifications with online documentation.
     View Compliance List Organized by Product
     View/Print Certificates of Compliance
     SIXNET Industrial Product Warranty
 

SIXNET provides you with the industrial certifications that you need:

 ISO9001 Certified:


www.iso.ch

SIXNET is a "Total Quality" company and has been ISO9001 certified since 1996. The International Organization for Standardization defines the ISO standards. Please review our:
   
Total Quality Policy
    ISO 9001:2000 Certificate
    Mission Statement

 N.I.S.T. Traceable Analog I/O:

All SIXNET in-house calibrations on analog I/O are traceable to N.I.S.T. (National Institute of Standards and Technology) standards.

    View the certificate of calibration

 Hazardous Locations:



www.ul.com
www.csa.ca

Most SIXNET products have been tested or verified by Underwriters Laboratories to comply with UL1604 and CAN/CSA C22.2/213-M1987, Class I, Division 2, Groups A, B, C, D. Please reference UL File # E192531:

    View the USA listing online (web access required)
    View the Canada listing online (web access required)

(Note: The RM-PS-024-01F power supply meets the requirements for UL1604  but is not currently included in this report.)

 

EEx nA II T4 X

www.cenelec.org

Most SIXNET products have been tested or verified by SIXNET to CENELEC EN50021 (EEx nA II T4 X) for operation in Zone 2 hazardous locations.

    View the declaration of conformity

 

Most SIXNET products have been tested or verified by SIXNET to meet Council Directive 94/9/EEC (ATEX Directive) relating to Group II, Category 3 hazardous locations.

    View the declaration of conformity

 Safety of Programmable Controller and Related Components:



www.ul.com
www.csa.ca

Most SIXNET products have been tested or verified by Underwriters Laboratories to comply with UL508 and CAN/CSA C22.2/14-91M. Please reference UL File # E179490:

    View the USA listing online (web access required)
    View the Canada listing online (web access required)

 Directive Compliance for the European Community:


www.europa.eu.int

All current SIXNET products are designed, manufactured, and verified to comply with the following European Union (EU) directives, as applicable:

  • EMC Directive - Council Directive 89/336/EC relating to ElectroMagnetic Compatibility
  • Low Voltage Directive - Council Directive 73/23/EC relating to electrical safety of "low voltage" devices
  • RTTE Directive - Council Directive 99/5/EC relating to Radio and Telecommunications Terminal Equipment
  • ATEX Directive - Council Directive 94/9/EC relating to equipment and protective systems intended for use in potentially explosive atmospheres (SIXNET complies for Group II, Category 3 locations)
  • RoHS Directive - Council Directive 2002/95/EC relating to the Restriction of Hazardous Substances (SIXNET is in the process of complying to RoHS - see RoHS Compliance Statement)

    View the declaration of conformity

For details on CE please go to:

 Safety for the European Community: (see CE links above)


www.europa.eu.int

Most SIXNET products are designed, manufactured, and verified to comply with EN61010 (Switches, I/O, Controller, & RTU products) or EN60950 (modem products).

    View the declaration of conformity

 Immunity for the European Community: (see CE links above)


www.europa.eu.int

Representative samples of most SIXNET products were tested and verified by a third party test lab and/or SIXNET. The samples were found to be immune to radiated RFI, ESD, and line-conducted burst interference in accordance with EN50082-1 or EN61326-1.

    View the declaration of conformity

This includes compliance with the standards listed below (as applicable):

  • EN61000-4-2 (IEC801-2) – ESD immunity
  • EN61000-4-3 / ENV50204 (IEC801-3 / ENV50140) – Radiated immunity
  • EN61000-4-4 (IEC801-4) – Fast transient immunity
  • EN61000-4-5 (ENV50142) – Surge immunity
  • EN61000-4-6 (ENV50141) – Conducted immunity
  • EN61000-4-8 – Magnetic fields immunity
  • EN61000-4-11 – Voltage interrupts immunity
 Emissions for the European Community: (see CE links above)



www.europa.eu.int

Representative samples of most  SIXNET products were tested by a third part test lab. The samples were found to be within acceptable limits for radiated and line conducted emissions per EN55022 or EN61326-1.

    View the declaration of conformity.

 Emissions for the USA and Canada:



www.fcc.gov

Representative samples of most  SIXNET products were tested by a third party test lab.  The samples were found to comply with FCC Part 15 - Subpart B, DOC Regulation CRC - c.1374, and Industry Canada Notice ICES-003, Issue 2.

    View the verification documents

 TELCOM for Telephone Modem Products:



www.fcc.gov

Representative samples of the VT-MODEM were tested by a third party test lab.  The samples were found to comply with limits for a Class B computing device pursuant to Subpart J of Part 15, and Part 68 of FCC rules. The FCC registration number is 5KN-USA-34579-MD-E.

    View the verification documents


www.ic.gc.ca

The VT-MODEM has been certified by Industry Canada to Specification CS03, Issue 8. The Industry Canada certification number is 2991 8926 A.



www.aca.gov.au

The VT-MODEM has been certified by an approved third party test lab in Australia to meet the following standards: ACA TS001-1997, ACA TS002-1997, AS/NZS3260-1993 (incl. amendments 1,2,3,4), AS/NZS3548-1993 (incl. amendments 1,2), IEC950-1991 (incl. amendments 1,2,3,4).

    View the verification documents

 Marine & Offshore Locations:


www.dnv.com

Representative samples of most SIXNET products were tested by Det Norske Veritas to DNV Certification No. 2.4 for Class A and B locations. This testing includes compliance with all the standards listed below.

    View the type approval at www.dnv.com
   
View the type approval certificate
    View the type approval test report summaries

DNV # IEC/EN Standard Test Description
3.6.2 60068-2-6 (Fc) Sinusoidal Vibration 3-13.2Hz: ±1mm / 13.2-100Hz: 0.7g
3.7 600 68-2-2 (Bb,Bd) Dry Heat 70°C / 16 hours
3.8 600 68-2-30 (Db) Damp Heat Two cycles, each 24 hours, 20/55°C, 95% RH
3.9 60068-2-1 Cold 0°C / 16 hours
3.4 60092-504 Power Supply Failure

3 interruptions, 30s duration

3.5 60092-504 Power Supply Variation

Four combo. of ±10% volt deviation & ±5% frequency deviation

3.12 60092-504 Insulation Resistance

Power lines - gnd: >100Mohm / >10Mohm

3.13 60092-504 High Voltage

1500V line to gnd: / 1min

3.14.9 61000-4-2 Electrostatic Discharge

±8kV air discharge / ±6 kV contact discharge

3.14.5 61000-4-4 Electrical Fast Transient / Burst

Power lines: ±2kV / Signal lines: ±1kV

3.14.6 61000-4-5 Electrical Slow Transient / Surge

Power input: ±0.5 kV, line-line / ±1kV, line-earth

3.14.8

61000-4-3

Radiated Susceptibility

80 MHz - 3GHz / 10 V/m 80% AM 1kHz

3.14.7 61000-4-6 Conducted High Frequency

Power input/Signal: 10 KHz-80MHz / 3V / 80% AM

3.14.4 60945 Conducted Low Frequency

Power input (110VAC): 0.05-10KHz

3.15.3 60533 / 50081-2 Radiated Emissions

30-1000MHz

3.15.3 60533 / 50081-2 Conducted Emissions

10KHz-20MHz

3.2 - Visual Inspection

Electrical/mechanical construction & workmanship

3.11 IEC 92-504 Inclination

Static and dynamic

 Products
CE
FCC
DNV
UL
508
cUL
(CSA)
UL
1604
cUL
(CSA)
Zone 2
, ATEX
C-Tick
ST-IPM-####
SixTRAK IPm Open Controller
-

VT-IPM-#### & VT-MIPM-###
VersaTRAK IPm RTU

-
ST-GT-1210
SixTRAK I/O Controller
-
SR-4160-##
RemoteLog RTU and Datalogger
-
I/O Module
EtherTRAK, SixTRAK, RemoteTRAK
-
ET-GT-#ES-###
Industrial Ethernet Switches
-
VT-MODEM-###
Industrial Telephone Modems
Industrial Ethernet Switches & Modems
BlueTree Wireless Data
What's new with SIXNET Automation

Certified to Perform
SIXNET Industrial Certifications


SIXNET Home