 Standards and Certifications
Below is general information on ratings and certifications for SIXNET connectivity products. Refer to the specification page or datasheet for each product to see the applicable standards.
     View Compliance List Organized by Product
     View/Print Certificates of Compliance
     SIXNET Industrial Product Warranty
 

SIXNET provides you with the industrial certifications that you need:

 ISO9001 Certified:


www.iso.ch

SIXNET is a "Total Quality" company and has been ISO9001 certified since 1996. The International Organization for Standardization defines the ISO standards. Please review our:
   
Total Quality Policy
    ISO 9001:2000 Certificate
    Mission Statement

 Hazardous Locations:



www.ul.com
www.csa.ca

Many SIXNET connectivity products have been tested or verified by Underwriters Laboratories to comply with UL1604 and CAN/CSA C22.2/213-M1987, Class I, Division 2, Groups A, B, C, D. Please reference UL File # E192531:

    View the USA listing online (web access required)
    View the Canada listing online (web access required)

 

EEx nA II T4 X

www.cenelec.org

Many SIXNET connectivity products have been tested or verified by SIXNET to EN50021/EN60079-15 (EEx nA II T4 X) for operation in Zone 2 hazardous locations.

    View the declaration of conformity

 

Many SIXNET connectivity products have been tested or verified by SIXNET to meet Council Directive 94/9/EEC (ATEX Directive) relating to Group II, Category 3 hazardous locations.

    View the declaration of conformity

 General Electrical Safety:



www.ul.com
www.csa.ca

Most SIXNET connectivity products have been tested or verified by Underwriters Laboratories to comply with UL508 and CAN/CSA C22.2/14-91M. Please reference UL File # E179490:

    View the USA listing online (web access required)
    View the Canada listing online (web access required)

 Directive Compliance for the European Community:


www.europa.eu.int

SIXNET connectivity products are designed, manufactured, and verified to comply with the following European Union (EU) directives, as applicable:

  • EMC Directive - Council Directive 89/336/EC relating to ElectroMagnetic Compatibility
  • Low Voltage Directive - Council Directive 73/23/EC relating to electrical safety of "low voltage" devices
  • RTTE Directive - Council Directive 99/5/EC relating to Radio and Telecommunications Terminal Equipment
  • ATEX Directive - Council Directive 94/9/EC relating to equipment and protective systems intended for use in potentially explosive atmospheres (SIXNET complies for Group II, Category 3 locations)
  • RoHS Directive - Council Directive 2002/95/EC relating to the Restriction of Hazardous Substances (SIXNET is in the process of complying to RoHS - see RoHS Compliance Statement)

    View the declaration of conformity

For details on CE please go to:

 Safety for the European Community: (see CE links above)


www.europa.eu.int

Most SIXNET connectivity products are designed, manufactured, and verified to comply with European electrical safety standards EN 61010 or EN 60950 as applicable.

    View the declaration of conformity

 Immunity for the European Community: (see CE links above)


www.europa.eu.int

SIXNET connectivity products have been tested and verified by a third party test lab and/or SIXNET. The samples were found to be immune to radiated RFI, ESD, and line-conducted burst interference in accordance with EN 50082-1 or EN 61326-1.

    View the declaration of conformity

This includes compliance with the standards listed below (as applicable):

  • EN61000-4-2 (IEC801-2) – ESD immunity
  • EN61000-4-3 / ENV50204 (IEC801-3 / ENV50140) – Radiated immunity
  • EN61000-4-4 (IEC801-4) – Fast transient immunity
  • EN61000-4-5 (ENV50142) – Surge immunity
  • EN61000-4-6 (ENV50141) – Conducted immunity
  • EN61000-4-8 – Magnetic fields immunity
  • EN61000-4-11 – Voltage interrupts immunity
 Emissions for the European Community: (see CE links above)



www.europa.eu.int

SIXNET connectivity products have been tested by a third part test lab and/or SIXNET. The samples were found to be within acceptable limits for radiated and line conducted emissions per EN 55022 or EN 61326-1.

    View the declaration of conformity.

 Emissions for the USA and Canada:



www.fcc.gov

All SIXNET connectivity products have been tested by a third party test lab and/or SIXNET.  The samples were found to comply with FCC Part 15 - Subpart B, DOC Regulation CRC - c.1374, and Industry Canada Notice ICES-003, Issue 2.

    View the verification documents

 Marine & Offshore Locations:

Many SIXNET connectivity products have been tested and/or type approved by Det Norske Veritas to DNV Certification No. 2.4 for Class A and B locations. This testing includes compliance with all the standards listed below.

    View the type approval at www.dnv.com
   
View the type approval certificate
   
View the verification documents

DNV # IEC/EN Standard Test Description
3.6.2 60068-2-6 (Fc) Sinusoidal Vibration 3-13.2Hz: ±1mm / 13.2-100Hz: 0.7g
3.7 600 68-2-2 (Bb,Bd) Dry Heat 70°C / 16 hours
3.8 600 68-2-30 (Db) Damp Heat Two cycles, each 24 hours, 20/55°C, 95% RH
3.9 60068-2-1 Cold 0°C / 16 hours
3.4 60092-504 Power Supply Failure

3 interruptions, 30s duration

3.5 60092-504 Power Supply Variation

Four combo. of ±10% volt deviation & ±5% frequency deviation

3.12 60092-504 Insulation Resistance

Power lines - gnd: >100Mohm / >10Mohm

3.13 60092-504 High Voltage

1500V line to gnd: / 1min

3.14.9 61000-4-2 Electrostatic Discharge

±8kV air discharge / ±6 kV contact discharge

3.14.5 61000-4-4 Electrical Fast Transient / Burst

Power lines: ±2kV / Signal lines: ±1kV

3.14.6 61000-4-5 Electrical Slow Transient / Surge

Power input: ±0.5 kV, line-line / ±1kV, line-earth

3.14.8

61000-4-3

Radiated Susceptibility

80 MHz - 3GHz / 10 V/m 80% AM 1kHz

3.14.7 61000-4-6 Conducted High Frequency

Power input/Signal: 10 KHz-80MHz / 3V / 80% AM

3.14.4 60945 Conducted Low Frequency

Power input (110VAC): 0.05-10KHz

3.15.3 60533 / 50081-2 Radiated Emissions

30-1000MHz

3.15.3 60533 / 50081-2 Conducted Emissions

10KHz-20MHz

3.2 - Visual Inspection

Electrical/mechanical construction & workmanship

3.11 IEC 92-504 Inclination

Static and dynamic

 
 TELCOM for Telephone Modem Products:



www.fcc.gov

The VT-MODEM was tested by a third party test lab and/or SIXNET.  The product complies with limits for a Class B computing device pursuant to Subpart J of Part 15, and Part 68 of FCC rules. The FCC registration number is 5KN-USA-34579-MD-E.

    View the verification documents


www.ic.gc.ca

The VT-MODEM has been certified by Industry Canada to Specification CS03, Issue 8. The Industry Canada certification number is 2991 8926 A.



www.aca.gov.au

The VT-MODEM has been certified by an approved third party test lab in Australia to meet the following standards: ACA TS001-1997, ACA TS002-1997, AS/NZS3260-1993 (incl. amendments 1,2,3,4), AS/NZS3548-1993 (incl. amendments 1,2), IEC950-1991 (incl. amendments 1,2,3,4).

    View the verification documents

 Product
CE
FCC
DNV
UL
508
cUL
(CSA)
UL
1604
cUL
(CSA)
Zone 2
C-Tick
Ethernet Switches
-
VT-MODEM-###
Industrial Telephone Modems
Ethernet Fiber Converters
-
Ethernet Modbus Gateways
-
Device Servers
-
-
Power Supplies
-

Certified to Perform
Industrial Certifications

 
SIXNET Home