Ensure
Your Military Vehicle or Industrial Application Stays Communicating!
SIXNET has
a variety of industrial Ethernet switch models that are designed
to meet MIL-STD-1275 A and B which defines the power requirements
for 24VDC military vehicles. Devices used in these vehicles require
extreme power protection because the power can fluctuate drastically
(7V ripple, 100V surges and 250V spikes) depending on operating
conditions (start-up, battery or generator failure, etc.) SIXNET
industrial Ethernet switches have been used in many demanding
military applications, such
as the Stryker LAV (Light Armored Vehicle). |

EB-GT-8ES-1EP
ET-5xS-IP67 (-E models)
|
|
MIL-STD-1275A/B
Summary:
Requirement |
Fault
Free |
Battery
Only |
Generator
Only |
Steady
State |
25-30VDC |
20-27VDC |
23-33VDC |
Ripple |
2V |
2V |
7V |
Spike |
+/-250V |
+/-250V |
+/-250V |
Surge |
40V,
50mS |
- |
100V,
50mS |
Starting |
|
28VDC,
5A |
6V-16V,
1S;
16V, 30S |
Click
here for a more detailed summary. |